Products
Rat INS(Insulin) ELISA Kit

This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti INS antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with INS bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of INS in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- ER1113
- Alias:
- Insulin ELISA Kit, INS ELISA Kit
- Species:
- Rat
- Range:
- 78.125-5000pg/ml
- Sensitivity:
- 46.875pg/ml
Size | Price |
---|---|
96T | Inquiry |
48T | Inquiry |
- SPECIFICATIONS
- CITATIONS
- FIGURES
- CONDITIONS
- FAQS
- Product Name
- Rat INS(Insulin) ELISA Kit
- Alias
- Insulin ELISA Kit, INS ELISA Kit
- Catalogue No.
- ER1113
- Size
- 48T/96T
- Species
- Rat
- UniProt ID
- P01322
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Sandwich ELISA, Double Antibody
- Detection Wavelength
- OD450
- Reaction Duration
- 4 hours
- Range
- 78.125-5000pg/ml
- Sensitivity
- 46.875pg/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with INS , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E003 Lyophilized Biotin-labeled Antibody(Concentrated) 1vial 1vial E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E024 TMB Substrate 5ml 10ml E005 Purified Water 200ul 200ul 2-8°C E039 Sample Dilution Buffer 10ml 20ml E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
- Washing: Wash the plate twice without immersing.
- Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
- Washing: Wash the plate three times and immerse for 1min each time.
- Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
- Washing: Wash the plate five times and immerse for 1min each time.
- Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
- Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
STD.(pg/ml) OD-1 OD-2 Average 0 0.103 0.105 0.104 78.125 0.171 0.175 0.173 156.25 0.23 0.236 0.233 312.5 0.419 0.431 0.425 625 0.676 0.696 0.686 1250 1.086 1.118 1.102 2500 1.582 1.628 1.605 5000 2.075 2.135 2.105 - Recovery
-
Add a certain amount of INS into the sample. Calculate the recovery by comparing the measured value with the expected amount of INS in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 85-103 93 EDTA plasma(n=10) 91-102 97 Heparin plasma(n=10) 85-103 96 - Linearity
-
Dilute the sample with a certain amount of INS at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 87-105% 83-98% 90-100% EDTA plasma(n=10) 89-97% 84-98% 93-100% Heparin plasma(n=10) 91-104% 82-100% 81-96% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (pg/ml) 161.7 630.2 2480 160.2 622.5 2448 Standard deviation 8.05 30.63 119.04 8.49 32.62 130.72 CV(%) 4.98 4.86 4.8 5.3 5.24 5.34 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100
- Journal:
- Pharmaceutics
- Cited Date:
- 2022-03-24
- Product:
- Journal:
- International Journal of Molecular Sciences
- Cited Date:
- 2022-11-10
- Product:
- Journal:
- BioFactors
- Author:
- Department of Physiology, Faculty of Medical Sciences, University of Kragujevac, Kragujevac, Serbia
- Cited Date:
- 2024-02-18
- Product:
- Journal:
- Frontiers in Pharmacology
- Cited Date:
- 2022-09-30
- Product:
- Journal:
- The Pharma Innovation Journal
- Cited Date:
- 2019-09-10
- Product:
- Journal:
- International Journal of Pharmaceutics
- Author:
- Biochemistry Department, Faculty of Science, Alexandria University, Alexandria, Egypt; Bio-Screening and Preclinical Trial Lab, Biochemistry Department, Faculty of Science, Alexandria University, Alexandria, Egypt.
- Cited Date:
- 2024-05-17
- Product:
- Journal:
- Phytomedicine Plus
- Cited Date:
- 2021-09-02
- Product:
- Journal:
- Journal of Pharmaceutical Investigation
- Author:
- Biochemistry Department, Faculty of Science, Alexandria University, Alexandria, 21515, Egypt
- Sample:
- serum
- Cited Date:
- 2024-08-30
- Product:
- Journal:
- Diabetes Research and Clinical Practice
- Author:
- Department of Exercise Physiology, Faculty of Sport Sciences, Shahid Chamran University of Ahvaz, Ahvaz, Iran.
- Cited Date:
- 2024-04-26
- Product:
- Journal:
- Pharmaceutics
- Author:
- Department of Biological Sciences, Faculty of Science, Beirut Arab University, Beirut 1107-2020, Lebanon
- Sample:
- serum
- Cited Date:
- 2024-07-26
- Product:
- Journal:
- Biomedicines
- Author:
- Department of Biochemistry, Faculty of Pharmacy, Suez Canal University, Ismailia 41522, Egypt
- Cited Date:
- 2023-12-29
- Product:
- Journal:
- Frontiers in Physiology
- Cited Date:
- 2021-09-10
- Product:
- Journal:
- Pfl眉gers Archiv - European Journal of Physiology
- Author:
- Department of Physiology, Faculty of Medicine, Tanta University, Tanta, Egypt
- Cited Date:
- 2023-08-18
- Product:
- Journal:
- Pharmaceuticals
- Author:
- Department of Anatomy, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Kuala Lumpur 56000, Malaysia
- Sample:
- serum
- Cited Date:
- 2024-11-08
- Product:
-
- Rat INS(Insulin) ELISA Kit
- Rat TNF-α(Tumor Necrosis Factor Alpha) ELISA Kit
- Rat PPAR-γ(Peroxisome ProlifeRator-Activated Receptor γ) ELISA Kit
- Rat IL-1β(Interleukin 1 Beta) ELISA Kit
- Rat HSD11B1(Corticosteroid 11-beta-dehydrogenase isozyme 1) ELISA Kit
- Rat CORT(Corticosterone) ELISA Kit
- Rat Lep(Leptin) ELISA Kit
- Rat IL-6(Interleukin-6) ELISA Kit
- Rat ADP/Acrp30(Adiponectin) ELISA Kit
- Journal:
- Pharmaceuticals
- Cited Date:
- 2021-03-25
- Product:
- Journal:
- Frontiers in Microbiology
- Cited Date:
- 2019-03-04
- Product:
- Journal:
- Heliyon
- Author:
- Animal Reproduction, Veterinary Research division, National Research Centre, Dokki, Giza, Egypt
- Sample:
- plasma
- Cited Date:
- 2024-05-06
- Product:
- Journal:
- Food and Chemical Toxicology
- Cited Date:
- 2019-01-18
- Product:
- Journal:
- Food Science & Nutrition
- Author:
- Department of Nutrition and Food Safety, School of Public Health, Fujian Medical University, Fuzhou, Fujian, China
- Sample:
- serum
- Cited Date:
- 2024-03-15
- Product:
- Journal:
- Biology of Reproduction
- Author:
- Poznan University of Life Sciences Laboratory of Neurobiology, Faculty of Veterinary Medicine and Animal Science, , Wojska Polskiego 71C, 60-625, Poznan, Poland
- Cited Date:
- 2023-09-08
- Product:
- Journal:
- Life Sciences
- Cited Date:
- 2020-03-21
- Product:
- Journal:
- Drug Delivery and Translational Research
- Cited Date:
- 2018-03-20
- Product:
- Journal:
- Journal of Molecular Histology
- Author:
- Clinical Pharmacology Department, Faculty of Medicine, Alexandria University, Alexandria, Egypt.
- Cited Date:
- 2025-02-07
- Product:
- Journal:
- Endocrine, Metabolic & Immune Disorders-Drug Targets
- Cited Date:
- 2022-02-24
- Product:
- Journal:
- Pharmaceutical Development and Technology
- Author:
- Department of Pharmacology and Toxicology, Faculty of Pharmacy, Zagazig University, Zagazig, 44519, Egypt.
- Cited Date:
- 2024-09-27
- Product:
- Journal:
- Tissue and Cell
- Author:
- Hormones Department, Medical Research and Clinical Studies Institute, National Research Centre, Dokki, Giza, Egypt
- Cited Date:
- 2023-12-01
- Product:
- Journal:
- Beni-Suef University Journal of Basic and Applied Sciences
- Author:
- Department of Human Physiology, Faculty of Basic Medical Sciences, College of Medical Sciences, Abubakar Tafawa Balewa University, Bauchi, Nigeria
- Sample:
- serum
- Cited Date:
- 2025-01-10
- Product:
- Journal:
- Fundamental & Clinical Pharmacology
- Cited Date:
- 2018-09-14
- Product:
- Journal:
- Molecular Biology Reports
- Cited Date:
- 2022-06-03
- Product:
- Journal:
- Chinese Journal of Integrative Medicine
- Author:
- School of Preclinical Sciences, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, 30000, Thailand.
- Cited Date:
- 2024-07-05
- Product:
- Journal:
- Archives of Oral Biology
- Author:
- Department of Surgical Dentistry and Maxillofacial Surgery, Dagestan State Medical, University of the Ministry of Health, 47 Lyakhova St., 367000 Mahachkala, Dagestan Republic, Russian Federation.
- Cited Date:
- 2024-09-13
- Product:
- Journal:
- PeerJ
- Cited Date:
- 2018-05-23
- Product:
- Journal:
- Current Research in Physiology
- Author:
- School of Preclinical Sciences, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, 30000, Thailand.
- Sample:
- blood samples
- Cited Date:
- 2025-02-07
- Product:
- Journal:
- Iranian Journal of Basic Medical Sciences
- Author:
- Department of Histology, Faculty of Veterinary Sciences, Ilam University, Ilam, Iran.
- Sample:
- serum
- Cited Date:
- 2024-11-22
- Product:
- Journal:
- Medical sicence monitor
- Cited Date:
- 2019-12-11
- Product:
- Journal:
- Genes & Genomics
- Cited Date:
- 2022-06-03
- Product:
- Journal:
- Nutrition & Food Science
- Cited Date:
- 2021-05-27
- Product:
- Journal:
- Nutrition & Food Science
- Cited Date:
- 2022-02-18
- Product:
- Journal:
- Malaysian Journal of Medical Sciences
- Cited Date:
- 2022-07-21
- Product:
- Journal:
- Current Research in Nutrition and Food Science
- Author:
- Department of Agricultural Products Technology, Faculty of Agricultural Technology, Universitas Semarang, Semarang, Indonesia.
- Cited Date:
- 2025-02-28
- Product:
- Journal:
- European Journal of Inflammation
- Cited Date:
- 2018-05-14
- Product:
- Journal:
- Journal of Clinical Practice and Research
- Author:
- Department of Biophysics, Ayd?n Adnan Menderes University, Institute of Health Sciences, Ayd?n, Türkiye
- Sample:
- serum
- Cited Date:
- 2024-12-13
- Product:
-
- Rat INS(Insulin) ELISA Kit
- Rat MDA(Malonaldehyde) ELISA Kit
- Rat TNF-α(Tumor Necrosis Factor Alpha) ELISA Kit
- Rat IL-1β(Interleukin 1 Beta) ELISA Kit
- Rat HbA1C(Glycosylated Hemoglobin/Hemoglobin A1c) ELISA Kit
- Rat SOD1(Superoxide dismutase [Cu-Zn]) ELISA Kit
- Rat Cat(Catalase) ELISA Kit
- Rat IL-6(Interleukin-6) ELISA Kit
- Journal:
- Journal of Medical and Life Science
- Author:
- Department of Zoology, Faculty of Science, Alexandria University, Alexandria, Egypt
- Sample:
- serum
- Cited Date:
- 2025-02-14
- Product:
- Journal:
- Harran University Journal of The Faculty of Veterinary Medicine
- Author:
- Batman University, Vocational School of Healthcare Studies, Batman, Türkiye
- Sample:
- serum
- Cited Date:
- 2024-07-05
- Product:
- Journal:
- BioMedicine
- Author:
- Faculty of Medicine, Universitas Riau, Pekanbaru, Indonesia
- Sample:
- serum
- Cited Date:
- 2024-09-06
- Product:
- Journal:
- Current Drug Discovery Technologies
- Cited Date:
- 2022-09-22
- Product:
- Journal:
- Future Science OA
- Cited Date:
- 2022-09-22
- Product:
- Journal:
- The Indonesian Biomedical Journal
- Author:
- Division Endocrinology, Department of Internal Medicine, Faculty of Medicine, Universitas Diponegoro, Jl. Prof. Soedarto No.13, Semarang 50275, Indonesia
- Sample:
- serum
- Cited Date:
- 2024-07-12
- Product:
- Journal:
- Current Nutrition & Food Science
- Cited Date:
- 2022-09-23
- Product:
- Journal:
- Indonesian Journal of Nutrition and Food
- Author:
- Department of Nutrition Sciences, Faculty of Medicine, Diponegoro University, Semarang 50275, Indonesia
- Sample:
- serum
- Cited Date:
- 2025-02-28
- Product:
- Journal:
- Current Research in Nutrition and Food Science
- Cited Date:
- 2021-10-29
- Product:
- Journal:
- Pharmazie
- Author:
- Department of Pharmacology and Toxicology, Faculty of Pharmacy, South Valley University, Qena Governorate.
- Sample:
- serum
- Cited Date:
- 2024-07-12
- Product:
- Journal:
- Egyptian Journal of Chemistry
- Author:
- Department of Medicinal and Aromatic Plants Research, Pharmaceutical and Drug Industries Research Institute, National Research Centre, 33 El Bohouth St., Dokki, Giza 12622, Egypt.
- Sample:
- plasma
- Cited Date:
- 2024-05-06
- Product:
- Journal:
- The 8th International Conference on Mathematics, Science and Education (ICMSE)
- Author:
- Department of Pharmacology and Clinical Pharmacy, Nusaputera College of Pharmaceutical Science, Semarang, Indonesia
- Cited Date:
- 2023-06-23
- Product:
- Journal:
- Tropical Journal of Natural Product Research
- Author:
- Medicine and Health Sciences Doctoral Study Program, Faculty of Medicine, Diponegoro University, Semarang, Central Java Indonesia
- Cited Date:
- 2024-02-18
- Product:
- Journal:
- Journal of Physics: Conference Series
- Cited Date:
- 2019-11-19
- Product:
- Journal:
- Toxicology Reports
- Cited Date:
- 2022-05-27
- Product:
- Journal:
- Food Research
- Author:
- Department of Nutrition Science, Faculty of Medicine, Universitas Diponegoro, Semarang, Indonesia
- Cited Date:
- 2023-11-10
- Product:
- Journal:
- SSRN
- Cited Date:
- 2022-11-04
- Product:
- Journal:
- Tropical Life Sciences Research
- Cited Date:
- 2022-11-18
- Product:
- Journal:
- Natural Product Sciences
- Author:
- Department of Medicine, Faculty of Medicine, Universitas Diponegoro, Semarang, Indonesia
- Cited Date:
- 2023-08-18
- Product:
- Journal:
- ADMET & DMPK
- Author:
- Department of Biochemistry, Yanka Kupala State University of Grodno, Bulvar Leninskogo Komsomola, 5, 230009 Grodno, Grodno, Belarus
- Sample:
- serum
- Cited Date:
- 2025-03-28
- Product:
- Journal:
- Indonesian Journal of Pharmaceutical Science and Technology
- Author:
- Fakultas Farmasi, Universitas Muhammadiyah Surakarta, Indonesia
- Cited Date:
- 2023-11-24
- Product:
- Journal:
- Jurnal Gizi dan Pangan
- Cited Date:
- 2020-03-02
- Product:
- Journal:
- Phytomedicine Plus
- Cited Date:
- 2020-12-10
- Product:
- Journal:
- The Indonesian Biomedical Journal
- Author:
- Department of Nursing, Faculty of Nursing, Politeknik Kesehatan Kemenkes Malang, Jl. Besar Ijen 77C, Malang 65112, Indonesia
- Cited Date:
- 2023-09-01
- Product:
- Journal:
- Phytomedicine Plus
- Author:
- Dairy Department, Food Industries and Nutrition Research Institute, National Research Centre, Cairo 12622, Egypt
- Species:
- blood samples
- Cited Date:
- 2024-06-14
- Product:
- Journal:
- Pharmazie
- Author:
- Department of Pharmacology and Toxicology, Faculty of Pharmacy, South Valley University, Qena, 83523, Egypt.
- Sample:
- serum
- Cited Date:
- 2024-10-25
- Product:
- Journal:
- Slovak Journal of Food Sciences
- Cited Date:
- 2022-02-18
- Product:
- Journal:
- The Medical Journal of Cairo University
- Author:
- Departments of Physiology, Faculty of Medicine, Suez Canal University
- Cited Date:
- 2023-05-05
- Product:
- Journal:
- Jurnal Veteriner
- Cited Date:
- 2019-05-24
- Product:
What’s the plate size in FineTest® ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
How about the shelf life and stability of FineTest® ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest® ELISA Kits have been subject to strict quality test.
Which cloned antibodies for FineTest® ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
Can I mix reagents from different batches of FineTest® ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
Can standard curve be extended to any direction?
FineTest® can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
Why does detection for serum/plasma sample by FineTest® ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.
How many samples can FineTest® ELISA Kits detect?
It depends on whether duplicate assay for your sample is required. Such as, you can detect 80 samples without duplication or 40 samples.
Why is sample loading conducted after equilibrating all kits’ components and samples to room temperature?
Temperature is the important factor for ELISA binding reaction. The reaction of samples at a consistent temperature requires for equilibrating all reagents to room temperature before the assay, including tested samples. Avoid the inaccurate ELISA assay results caused by temperature differences.
Why is duplicate assay suggested for ELISA assay?
To get more accurate assay results, it's strongly suggested to conduct duplicate assay for the standard and sample. Duplicate assay can calculate average value to ensure more accurate assay results and solve drift caused by misoperation during the assay. Calculation of CV evaluates experimental operation and precision of the ELISA kit.
How to get the standard curve with excellent linearity?
Follow the suggested method in the manual to store the standard. Before dissolving the standard, transient centrifugation is required to completely collect the powder. Confirm the fully dissolution and mixing of the standard(about 10min). Then, conduct steps of series dilution. Ensure the fully mixing and accurate pipetting in each step. Properly stop the staining. Choose suitable fitting equation to plot the standard curve.
Can ELISA plates be stacked together for incubation?
To keep the consistent environmental condition of all plates, stacking is not suggested during incubation.
Why is polypropylene tube used for standard dilution in some analyses?
Some proteins or analytes can bind with glass or polystyrene. However, they are not easy to bind with polypropylene tube.
When to stop ELISA reaction?
ELISA assay finally requires for enzyme-catalyzed substrate to complete the staining reaction. Stopping the reaction at the best time is the important factor for successful ELISA assay. When the blue complex appears after adding TMB substrate for 12min, read the O.D. absorbance at 620nm. The staining can be stopped, when the OD value of the darkest color at 620nm is between 0.8 - 0.9. The relevant OD value at 450nm for stopping the staining is between 2.0 - 2.5. If the OD value at 620nm is lower than 0.8, the staining duration can be properly extended.
Why is dual wavelength selected for reading in a microplate reader? What's the purpose of wavelength correction?
Dual wavelength for reading in ELISA assay mainly aims to remove non-specific background interference, and improve accuracy and reliability of the detection. FineTest® usually suggests to set the corrected wavelength as 570nm or 630nm in a microplate reader. The OD value may be higher when directly reading at 450nm. However, the accuracy is lower.
Why is 4 - pl curve fitting is required for generating standard curve?
FineTest® recommends to use ELISA curve fitting software and validate ELISA kit with 4 - pl curve fitting. 4 - pl curve fitting mainly aims to accurately describe the nonlinear dynamic characteristics of antigen - antibody binding. Thus, the quantitative accuracy of low or high concentration of sample is improved. Experimental errors are decreased. The reliability and reproducibility of assay results are ensured.
If sample OD value is higher than OD value of the highest point on the standard curve, what's the suggested solution?
Dilute the sample with dilution buffer and conduct the detection again. Ensure the detected value of the sample falls in the range of standard curve.
Are there any rewards to publish papers using FineTest® ELISA Kits?
If you published paper using FineTest® ELISA Kits, you will obtain US$150-US$550 coupon, please contact us for more details.