Products
Human IFN-γ(Interferon gamma) ELISA Kit

This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IFN-γ antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with IFN-γ bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IFN-γ in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- EH0164
- Alias:
- Interferon gamma ELISA Kit, IFN-gamma ELISA Kit, Immune interferon ELISA Kit, IFNG ELISA Kit
- Species:
- Human
- Range:
- 15.625-1000pg/ml (1pg=20mIU)
- Sensitivity:
- 9.375pg/ml
Size | Price |
---|---|
96T | Inquiry |
48T | Inquiry |
- SPECIFICATIONS
- CITATIONS
- FIGURES
- CONDITIONS
- FAQS
- Product Name
- Human IFN-γ(Interferon gamma) ELISA Kit
- Alias
- Interferon gamma ELISA Kit, IFN-gamma ELISA Kit, Immune interferon ELISA Kit, IFNG ELISA Kit
- Catalogue No.
- EH0164
- Size
- 48T/96T
- Species
- Human
- UniProt ID
- P01579
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Sandwich ELISA, Double Antibody
- Detection Wavelength
- OD450
- Reaction Duration
- 4 hours
- Range
- 15.625-1000pg/ml (1pg=20mIU)
- Sensitivity
- 9.375pg/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with IFN-γ , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E003 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul E024 TMB Substrate 5ml 10ml E039 Sample Dilution Buffer 10ml 20ml 2-8°C E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
- Washing: Wash the plate twice without immersing.
- Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
- Washing: Wash the plate three times and immerse for 1min each time.
- Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
- Washing: Wash the plate five times and immerse for 1min each time.
- Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
- Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
STD.(pg/ml) OD-1 OD-2 Average 0 0.033 0.035 0.034 15.625 0.097 0.102 0.099 31.25 0.173 0.182 0.177 62.5 0.266 0.279 0.271 125 0.534 0.561 0.545 250 0.844 0.887 0.861 500 1.441 1.514 1.47 1000 2.18 2.291 2.224 - Recovery
-
Add a certain amount of IFN-γ into the sample. Calculate the recovery by comparing the measured value with the expected amount of IFN-γ in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 90-99 97 EDTA plasma(n=10) 87-100 95 Heparin plasma(n=10) 85-105 97 - Linearity
-
Dilute the sample with a certain amount of IFN-γ at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 86-104% 90-105% 85-102% EDTA plasma(n=10) 84-99% 84-98% 83-98% Heparin plasma(n=10) 84-100% 82-91% 81-85% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (pg/ml) 31.47 130.3 510 32 123.1 501 Standard deviation 1.68 7.53 29.12 1.7 6.94 26.45 CV(%) 5.35 5.78 5.71 5.32 5.64 5.28 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100
- Journal:
- Annals of the Rheumatic Diseases
- Author:
- Department of Rheumatology and Immunology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Sample:
- serum
- Cited Date:
- 2024-03-08
- Product:
- Journal:
- Cancer Research
- Author:
- Fudan University Shanghai Cancer Center, Shanghai, China.
- Sample:
- supernatant
- Cited Date:
- 2024-09-20
- Product:
- Journal:
- Frontiers in Immunology
- Author:
- Museum and Institute of Zoology, Polish Academy of Science, Warsaw, Poland.
- Sample:
- hemolymph samples
- Cited Date:
- 2024-05-24
- Product:
-
- Human TNF-α(Tumor Necrosis Factor Alpha) ELISA Kit
- Human IL-6(Interleukin 6) ELISA Kit
- Human IL-13(Interleukin 13) ELISA Kit
- Human IL-17A(Interleukin 17 A) ELISA Kit
- Human IL-19(Interleukin 19) ELISA Kit
- Human TNF-β(Tumor Necrosis Factor Beta) ELISA Kit
- Human IL-2(Interleukin 2) ELISA Kit
- Human IL-3(Interleukin 3) ELISA Kit
- Human IL-7(Interleukin 7) ELISA Kit
- Human IL-8(Interleukin 8) ELISA Kit
- Human IL-12(Interleukin 12) ELISA Kit
- Human IL-15(Interleukin 15) ELISA Kit
- Human IL-1α(Interleukin 1 Alpha) ELISA Kit
- Human IL-1β(Interleukin 1 Beta) ELISA Kit
- Human GM-CSF(Granulocyte Macrophage Colony Stimulating Factor) ELISA Kit
- Human IFN-γ(Interferon gamma) ELISA Kit
- Human G-CSF(Granulocyte Colony Stimulating Factor 3) ELISA Kit
- Human M-CSF(Macrophage Colony-Stimulating Factor) ELISA Kit
- Journal:
- International Journal of Molecular Sciences
- Cited Date:
- 2022-07-29
- Product:
-
- Human IL-6(Interleukin 6) ELISA Kit
- Human IL-17 F(Interleukin 17F) ELISA Kit
- Human IL-17A(Interleukin 17 A) ELISA Kit
- Human IL-23(Interleukin 23) ELISA Kit
- Human IL-35 (Interleukin 35) ELISA Kit
- Human IL-21(Interleukin-21) ELISA Kit
- Human TGF-β1(Transforming Growth Factor Beta 1) ELISA Kit
- Human IL-22(Interleukin-22) ELISA Kit
- Human IL-10(Interleukin 10) ELISA Kit
- Human IFN-γ(Interferon gamma) ELISA Kit
- Journal:
- International Immunopharmacology
- Cited Date:
- 2023-04-14
- Product:
- Journal:
- Frontiers in Immunology
- Author:
- Department of Transplant Immunology and Stem Cell Lab, Global Medical Education and Research Foundation, Hyderabad, India
- Sample:
- serum
- Cited Date:
- 2025-02-28
- Product:
- Journal:
- International Journal of Molecular Sciences
- Author:
- Department of Biomedical Laboratory Sciences, School of Health Sciences, College of Medicine and Health Sciences, University of Rwanda, Kigali P.O. Box 3248, Rwanda
- Cited Date:
- 2023-08-11
- Product:
-
- Human IL-17 A/F(Interleukin 17A/F) ELISA Kit
- Human TNF-α(Tumor Necrosis Factor Alpha) ELISA Kit
- Human IL-6(Interleukin 6) ELISA Kit
- Human IL-13(Interleukin 13) ELISA Kit
- Human IgG(Immunoglobulin G) ELISA Kit
- Human IgM(Immunoglobulin M) ELISA Kit
- Human IL-4(Interleukin 4) ELISA Kit
- Human IL-10(Interleukin 10) ELISA Kit
- Human IFN-γ(Interferon gamma) ELISA Kit
- Journal:
- Cell Biology and Toxicology
- Author:
- Department of Urology, The Seventh Medical Center of Chinese PLA General Hospital, Beijing, 100700, P.R. China.
- Sample:
- homogenate supernatant
- Cited Date:
- 2025-01-03
- Product:
- Journal:
- Biochemical Pharmacology
- Author:
- Department of Thoracic Surgery, Xingtai People's Hospital, Xingtai 054000 Hebei, PR China.
- Cited Date:
- 2025-02-07
- Product:
- Journal:
- Scientific Reports
- Cited Date:
- 2023-03-09
- Product:
- Journal:
- International Journal of Molecular Sciences
- Author:
- Institute of Immunology, Faculty of Medicine, Comenius University Bratislava, 813 72 Bratislava, Slovakia
- Sample:
- serum
- Cited Date:
- 2025-01-10
- Product:
-
- Human IL-6(Interleukin 6) ELISA Kit
- Human SAKL(Soluble alpha-Klotho) ELISA Kit
- Human sTREM-1(soluble Triggering Receptor Expressed on Myeloid Cells-1) ELISA Kit
- Human IL-13(Interleukin 13) ELISA Kit
- Human VEGF(Vascular Endothelial Cell Growth Factor) ELISA Kit
- Human IL-4(Interleukin 4) ELISA Kit
- Human GDNF(Glial cell line-derived neurotrophic factor) ELISA Kit
- Human IFN-γ(Interferon gamma) ELISA Kit
- Human Fractalkine(Chemokine C-X3-C-Motif Ligand 1) ELISA Kit
- Journal:
- Cancers
- Author:
- Institute of Immunology, Faculty of Medicine, Comenius University in Bratislava, 811 08 Bratislava, Slovakia.
- Sample:
- serum
- Cited Date:
- 2024-11-29
- Product:
- Journal:
- Cytokine
- Author:
- Museum and Institute of Zoology, Polish Academy of Sciences, Twarda 51/55, 00-818 Warszawa, Poland.
- Sample:
- hemocyte culture
- Cited Date:
- 2024-11-22
- Product:
- Journal:
- Molecular Biotechnology
- Author:
- Department of Oncology, Nantong First People's Hospital, the Second Affiliated Hospital of Nantong University, Nantong City, 226000, Jiangsu, China
- Cited Date:
- 2024-01-26
- Product:
- Journal:
- Immunity, Inflammation and Disease
- Cited Date:
- 2023-03-24
- Product:
- Journal:
- Experimental and Therapeutic Medicine
- Cited Date:
- 2022-04-07
- Product:
- Journal:
- Jurnal Kesehatan Reproduksi
- Cited Date:
- 2019-05-29
- Product:
- Journal:
- International Food Research Journal
- Author:
- School of chemical and energy engineering, faculty of engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Bahru, Johor, Malaysia
- Cited Date:
- 2023-06-02
- Product:
- Journal:
- Medical Journal of Malaysia
- Cited Date:
- 2022-09-01
- Product:
- Journal:
- Exerc Sci.
- Cited Date:
- 2016-11-30
- Product:
- Journal:
- Research Square
- Cited Date:
- 2022-04-14
- Product:
- Journal:
- The Indonesian Biomedical Journal
- Cited Date:
- 2019-07-30
- Product:
- Journal:
- Research Square
- Author:
- Nizam's Institute of Medical Sciences
- Cited Date:
- 2023-06-16
- Product:
-
- Human TNF-α(Tumor Necrosis Factor Alpha) ELISA Kit
- Human IL-6(Interleukin 6) ELISA Kit
- Human FGF2(Heparin-binding growth factor 2) ELISA Kit
- Human VEGF(Vascular Endothelial Cell Growth Factor) ELISA Kit
- Human IL-4(Interleukin 4) ELISA Kit
- Human IL-8(Interleukin 8) ELISA Kit
- Human IL-10(Interleukin 10) ELISA Kit
- Human IL-1β(Interleukin 1 Beta) ELISA Kit
- Human IFN-γ(Interferon gamma) ELISA Kit
- Journal:
- Egyptian Journal of Ear, Nose, Throat and Allied Sciences
- Author:
- Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Brawijaya University/Dr. Saiful Anwar General Hospital, Malang, Indonesia
- Cited Date:
- 2023-11-17
- Product:
- Journal:
- Turkish Journal of Surgery
- Author:
- Department of Surgery, Jawaharlal Institute of Postgraduation Medical Education and Research (JIPMER), Puducherry, India
- Sample:
- blood samples
- Cited Date:
- 2024-10-18
- Product:
- Journal:
- Korean Journal of Otorhinolaryngology-Head and Neck Surgery
- Author:
- Departments of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Brawijaya University/Dr. Saiful Anwar General Hospital, Malang, Indonesia
- Cited Date:
- 2023-12-01
- Product:
- Journal:
- Journal of Ayurveda and Integrative Medicine
- Cited Date:
- 2021-08-12
- Product:
- Journal:
- bioRxiv
- Author:
- Human Microbiology Institute, New York, NY 10014, USA
- Sample:
- culture medium
- Cited Date:
- 2025-02-07
- Product:
What’s the plate size in FineTest® ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
How about the shelf life and stability of FineTest® ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest® ELISA Kits have been subject to strict quality test.
Which cloned antibodies for FineTest® ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
Can I mix reagents from different batches of FineTest® ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
Can standard curve be extended to any direction?
FineTest® can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
Why does detection for serum/plasma sample by FineTest® ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.
How many samples can FineTest® ELISA Kits detect?
It depends on whether duplicate assay for your sample is required. Such as, you can detect 80 samples without duplication or 40 samples.
Why is sample loading conducted after equilibrating all kits’ components and samples to room temperature?
Temperature is the important factor for ELISA binding reaction. The reaction of samples at a consistent temperature requires for equilibrating all reagents to room temperature before the assay, including tested samples. Avoid the inaccurate ELISA assay results caused by temperature differences.
Why is duplicate assay suggested for ELISA assay?
To get more accurate assay results, it's strongly suggested to conduct duplicate assay for the standard and sample. Duplicate assay can calculate average value to ensure more accurate assay results and solve drift caused by misoperation during the assay. Calculation of CV evaluates experimental operation and precision of the ELISA kit.
How to get the standard curve with excellent linearity?
Follow the suggested method in the manual to store the standard. Before dissolving the standard, transient centrifugation is required to completely collect the powder. Confirm the fully dissolution and mixing of the standard(about 10min). Then, conduct steps of series dilution. Ensure the fully mixing and accurate pipetting in each step. Properly stop the staining. Choose suitable fitting equation to plot the standard curve.
Can ELISA plates be stacked together for incubation?
To keep the consistent environmental condition of all plates, stacking is not suggested during incubation.
Why is polypropylene tube used for standard dilution in some analyses?
Some proteins or analytes can bind with glass or polystyrene. However, they are not easy to bind with polypropylene tube.
When to stop ELISA reaction?
ELISA assay finally requires for enzyme-catalyzed substrate to complete the staining reaction. Stopping the reaction at the best time is the important factor for successful ELISA assay. When the blue complex appears after adding TMB substrate for 12min, read the O.D. absorbance at 620nm. The staining can be stopped, when the OD value of the darkest color at 620nm is between 0.8 - 0.9. The relevant OD value at 450nm for stopping the staining is between 2.0 - 2.5. If the OD value at 620nm is lower than 0.8, the staining duration can be properly extended.
Why is dual wavelength selected for reading in a microplate reader? What's the purpose of wavelength correction?
Dual wavelength for reading in ELISA assay mainly aims to remove non-specific background interference, and improve accuracy and reliability of the detection. FineTest® usually suggests to set the corrected wavelength as 570nm or 630nm in a microplate reader. The OD value may be higher when directly reading at 450nm. However, the accuracy is lower.
Why is 4 - pl curve fitting is required for generating standard curve?
FineTest® recommends to use ELISA curve fitting software and validate ELISA kit with 4 - pl curve fitting. 4 - pl curve fitting mainly aims to accurately describe the nonlinear dynamic characteristics of antigen - antibody binding. Thus, the quantitative accuracy of low or high concentration of sample is improved. Experimental errors are decreased. The reliability and reproducibility of assay results are ensured.
If sample OD value is higher than OD value of the highest point on the standard curve, what's the suggested solution?
Dilute the sample with dilution buffer and conduct the detection again. Ensure the detected value of the sample falls in the range of standard curve.
Are there any rewards to publish papers using FineTest® ELISA Kits?
If you published paper using FineTest® ELISA Kits, you will obtain US$150-US$550 coupon, please contact us for more details.