Mouse anti-SARS-CoV2(S-RBD)(Omicron,B.1.1.529) IgG ELISA Kit

References 1 Category: Research Area:

This kit is based on indirect ELISA detection method and takes 3h assay time. The microplate provided in this kit has been precoated with antigen. HRP-antibody is used as detection antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add HRP-detection antibody, then it binds with anti-SARS-CoV2(S-RBD)IgG bound to precoated antibody. Wash unbound components and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of anti-SARS-CoV2(S-RBD)IgG in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.

Catalogue No.: 
EM2037
Alias: 
anti-SARS-CoV2(S-RBD)IgG ELISA Kit
Species: 
Mouse
Range: 
1.563-100ng/ml
Sensitivity: 
0.938ng/ml
  • SPECIFICATIONS
  • CITATIONS
Product Name
Mouse anti-SARS-CoV2(S-RBD)(Omicron,B.1.1.529) IgG ELISA Kit
Alias
anti-SARS-CoV2(S-RBD)IgG ELISA Kit
Catalogue No.
EM2037
Size
48T/96T
Species
Mouse
Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Method
HRP Antibody, Indirect ELISA Sandwich
Detection Wavelength
OD450
Reaction Duration
1.5 hours
Range
1.563-100ng/ml
Sensitivity
0.938ng/ml
Storage
2-8°C(Sealed), Don't cryopreserve.
Specificity
Specifically binds with anti-SARS-CoV2(S-RBD)IgG , no obvious cross reaction with other analogues.
ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit
E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C
E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C
E003 HRP Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light)
E024 TMB Substrate 5ml 10ml
E039 Sample Dilution Buffer 10ml 20ml 2-8°C
E040 Antibody Dilution Buffer 5ml 10ml
E026 Stop Solution 5ml 10ml
E038 Wash Buffer(Concentrated, 25X) 15ml 30ml
E006 Plate Sealer 3 pieces 5 pieces  
E007 Product Description 1 copy 1 copy
Required Instruments and Reagents
  1. Microplate reader (wavelength: 450nm)
  2. 37°C incubator (CO2 incubator for cell culture is not recommenced.)
  3. Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
  4. Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
  5. Sterile tubes and Eppendorf tubes with disposable tips
  6. Absorbent paper and loading slot
  7. Deionized or distilled water
Assay Procedure Summary
Elisa实验原理图
Standard Curve

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)

Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(ng/ml) OD-1 OD-2 Average
0 0.061 0.064 0.062
1.562 0.174 0.183 0.178
3.125 0.284 0.299 0.29
6.25 0.477 0.502 0.487
12.5 0.856 0.899 0.873
25 1.299 1.366 1.326
50 1.879 1.975 1.917
100 2.21 2.323 2.255
EM2037 Standard Curve Image
Recovery

Add a certain amount of anti-SARS-CoV2(S-RBD)IgG into the sample. Calculate the recovery by comparing the measured value with the expected amount of anti-SARS-CoV2(S-RBD)IgG in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 89-105 98
EDTA plasma(n=10) 89-105 97
Heparin plasma(n=10) 85-102 97
Linearity

Dilute the sample with a certain amount of anti-SARS-CoV2(S-RBD)IgG at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 87-102% 87-102% 88-94%
EDTA plasma(n=10) 88-99% 82-101% 84-101%
Heparin plasma(n=10) 87-98% 81-100% 81-91%
Precision(%)

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (ng/ml) 3.12 11.24 47.22 3.04 11.66 48.53
Standard deviation 0.14 0.61 2.52 0.16 0.61 2.24
CV(%) 4.42 5.46 5.34 5.37 5.25 4.62
Stability

Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.

ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months
Average(%) 80 95-100