Rat OVA sIgM(Ovalbumin Specific IgM) ELISA Kit
This kit is based on capture ELISA detection method and takes 3h assay time. The microplate provided in this kit has been precoated with anti Rat IgM(U-chain). HRP-antigen is used as detection antigen. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add HRP-antigen. Then, it binds with OVA sIgM bound to anti Rat IgM(U-chain). Wash unbound components and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of OVA sIgM in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- ER1217
- Alias:
- Ovalbumin Specific IgM ELISA Kit, OVA SIgM ELISA Kit
- Species:
- Rat
- Range:
- 12.5-800ng/ml
- Sensitivity:
- 7.5ng/ml
- SPECIFICATIONS
- Product Name
- Rat OVA sIgM(Ovalbumin Specific IgM) ELISA Kit
- Alias
- Ovalbumin Specific IgM ELISA Kit, OVA SIgM ELISA Kit
- Catalogue No.
- ER1217
- Size
- 48T/96T
- Species
- Rat
- UniProt No.
- CAS: 9006-59-1
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Capture ELISA
- Detection Wavelength
- OD450
- Reaction Duration
- 3 hours
- Range
- 12.5-800ng/ml
- Sensitivity
- 7.5ng/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with OVA sIgM , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E003 HRP-Antigen(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E024 TMB Substrate 5ml 10ml E039 Sample Dilution Buffer 10ml 20ml 2-8°C E040 Antigen Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
STD.(ng/ml) OD-1 OD-2 Average 0 0.08 0.084 0.082 12.5 0.172 0.181 0.176 25 0.246 0.258 0.251 50 0.403 0.424 0.412 100 0.632 0.664 0.645 200 1.073 1.128 1.095 400 1.636 1.72 1.67 800 2.082 2.188 2.124 - Recovery
-
Add a certain amount of OVA sIgM into the sample. Calculate the recovery by comparing the measured value with the expected amount of OVA sIgM in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 87-102 96 EDTA plasma(n=10) 89-104 95 Heparin plasma(n=10) 85-103 95 - Linearity
-
Dilute the sample with a certain amount of OVA sIgM at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 89-102% 82-97% 82-94% EDTA plasma(n=10) 85-99% 84-98% 83-98% Heparin plasma(n=10) 85-102% 84-98% 87-100% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (ng/ml) 23.4 98.5 401 24.5 100.7 393 Standard deviation 1.5 4.61 19.61 1.18 4.26 23.23 CV(%) 6.43 4.68 4.89 4.82 4.23 5.91 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100