- Catalog No.
- K079 
- Size
- 100mL/200mL/500mL 
- Kit components
- 
- 
| Reagents | 100mL | 200mL | 500mL | Storage |  - 
| Cell Staining Buffer | 100mL | 200mL | 500mL | 2-8°C |  
 
- Storage
- 2-8°C for 12 months 
- Introduction
- Cell Staining Buffer, a buffer optimized for sample preparation of flow cytometry (FCM), can be used in fluorescent antibody dilution and cell sample washes. - This product contains bovine serum albumin (BSA) as carrier protein to reduce non-specific binding of fluorescent antibodies. Experiments showed that addition of BSA can also reduce damage to cells during sample preparation and retain more cells for analysis. - This product contains EDTA as a chelating reagent for metallic ions which promote cell to cell adhesion. Addition of modest amount of EDTA can boost the ratio of singlets in FCM analysis.  - This product contains preservative to prevent bacterial contamination at a safe dosage to make sure that the impact on cells can be negligible. 
- Instructions
- This product is provided as 1×working buffer. It can be added directly into tubes containing cell pellets to resuspend. 
- Assay Protocol
- 1. Single cell suspensions are centrifuged at 300 g for 5 min, discard the supernatant. - 2. Add desired amount of Cell Staining Buffer with a pipettor to resuspend the cell pellets. For common analysis, 106 cells are resuspended with 100 μL buffer, i.e. with a cell density of 107 cells/mL. 
- Note
- 1.For your safety and health, please wear the lab coat and disposable gloves before the experiments. - 2.This reagent is for research use only.