Products
Mouse FLT1/VEGFR1(Vascular Endothelial Growth Factor Receptor 1) ELISA Kit
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti FLT1/VEGFR1 antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with FLT1/VEGFR1 bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of FLT1/VEGFR1 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- EM1028
- Alias:
- FLT1 ELISA Kit, VEGFR1 ELISA Kit, FLT1 ELISA Kit, Flt-1 ELISA Kit, FLT ELISA Kit, FLT-1 ELISA Kit, Fms-like tyrosine kinase 1 ELISA Kit, fms-related tyrosine kinase 1 ELISA Kit, vascular endothelial growth factor ELISA Kit, vascularpermeability factor receptor ELISA Kit, FRT ELISA Kit, Tyrosine-protein kinase FRT ELISA Kit, Tyrosine-protein kinase receptor FLT ELISA Kit, vascular endothelial growth factor receptor 1 ELISA Kit, Vascular permeability factor receptor ELISA Kit, VEGFR1 ELISA Kit, VEGFR-1 ELISA Kit
- Species:
- Mouse
- Range:
- 62.5-4000pg/ml
- Sensitivity:
- 37.5pg/ml
- SPECIFICATIONS
- Product Name
- Mouse FLT1/VEGFR1(Vascular Endothelial Growth Factor Receptor 1) ELISA Kit
- Alias
- FLT1 ELISA Kit, VEGFR1 ELISA Kit, FLT1 ELISA Kit, Flt-1 ELISA Kit, FLT ELISA Kit, FLT-1 ELISA Kit, Fms-like tyrosine kinase 1 ELISA Kit, fms-related tyrosine kinase 1 ELISA Kit, vascular endothelial growth factor ELISA Kit, vascularpermeability factor receptor ELISA Kit, FRT ELISA Kit, Tyrosine-protein kinase FRT ELISA Kit, Tyrosine-protein kinase receptor FLT ELISA Kit, vascular endothelial growth factor receptor 1 ELISA Kit, Vascular permeability factor receptor ELISA Kit, VEGFR1 ELISA Kit, VEGFR-1 ELISA Kit
- Catalogue No.
- EM1028
- Size
- 48T/96T
- Species
- Mouse
- UniProt No.
- P35969
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Sandwich ELISA, Double Antibody
- Detection Wavelength
- OD450
- Reaction Duration
- 4 hours
- Range
- 62.5-4000pg/ml
- Sensitivity
- 37.5pg/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with FLT1/VEGFR1 , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E003 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul E024 TMB Substrate 5ml 10ml E039 Sample Dilution Buffer 10ml 20ml 2-8°C E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
- Washing: Wash the plate twice without immersing.
- Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
- Washing: Wash the plate three times and immerse for 1min each time.
- Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
- Washing: Wash the plate five times and immerse for 1min each time.
- Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
- Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
STD.(pg/ml) OD-1 OD-2 Average 0 0.085 0.087 0.086 62.5 0.13 0.134 0.132 125 0.153 0.157 0.155 250 0.246 0.254 0.25 500 0.403 0.415 0.409 1000 0.663 0.683 0.673 2000 1.254 1.29 1.272 4000 2.165 2.227 2.196 - Recovery
-
Add a certain amount of FLT1/VEGFR1 into the sample. Calculate the recovery by comparing the measured value with the expected amount of FLT1/VEGFR1 in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 85-103 95 EDTA plasma(n=10) 88-100 95 Heparin plasma(n=10) 90-95 95 - Linearity
-
Dilute the sample with a certain amount of FLT1/VEGFR1 at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 82-100% 87-98% 86-98% EDTA plasma(n=10) 86-103% 86-105% 91-104% Heparin plasma(n=10) 84-92% 82-100% 82-91% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (pg/ml) 129.3 494.7 2042 128.1 496.2 2027 Standard deviation 6.22 27.11 95.77 6.43 26.55 102.36 CV(%) 4.81 5.48 4.69 5.02 5.35 5.05 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100