PARP1 antibody

Synonyms:Poly [ADP-ribose] polymerase 1 (PARP-1)|ADP-ribosyltransferase diphtheria toxin-like 1 (ARTD1)|DNA ADP-ribosyltransferase PARP1|NAD(+) ADP-ribosyltransferase 1 (ADPRT 1)|Poly[ADP-ribose] synthase 1|Protein poly-ADP-ribosyltransferase PARP1|Poly [ADP-ribose] polymerase 1 antibody, processed C-terminus Alternative names: Poly [ADP-ribose] polymerase 1 antibody, 89-kDa form|Poly [ADP-ribose] polymerase 1 antibody, processed N-terminus (NT-PARP-1) Alternative names: Poly [ADP-ribose] polymerase 1 antibody, 24-kDa form|Poly [ADP-ribose] polymerase 1 antibody, 28-kDa form|PARP1|ADPRT|PPOL antibody
Catalogue No.:FNab09939Reactivity:Human, Mouse, Rat
Host:MouseTested Application:ELISA, WB, IHC, IF
Clonality:monoclonalIsotype:IgG1
Size Price
100µg Inquiry
Dispatch Time: About 3 working days
  • SPECIFICATIONS
  • FIGURES
  • CONDITIONS
  • FAQS
Product Name
PARP1 antibody
Catalogue No.
FNab09939
Size
100μg
Form
liquid
Purification
protein A+G purified
Purity
≥95% as determined by SDS-PAGE
Clonality
monoclonal
Isotype
IgG1
Clone ID
4A9
Storage
PBS with 0.02% sodium azide and 50% glycerol pH 7.3, -20℃ for 12 months(Avoid repeated freeze / thaw cycles.)
Immunogen
Immunogen
poly (ADP-ribose) polymerase 1
Alternative Names
Poly [ADP-ribose] polymerase 1 (PARP-1)|ADP-ribosyltransferase diphtheria toxin-like 1 (ARTD1)|DNA ADP-ribosyltransferase PARP1|NAD(+) ADP-ribosyltransferase 1 (ADPRT 1)|Poly[ADP-ribose] synthase 1|Protein poly-ADP-ribosyltransferase PARP1|Poly [ADP-ribose] polymerase 1 antibody, processed C-terminus Alternative names: Poly [ADP-ribose] polymerase 1 antibody, 89-kDa form|Poly [ADP-ribose] polymerase 1 antibody, processed N-terminus (NT-PARP-1) Alternative names: Poly [ADP-ribose] polymerase 1 antibody, 24-kDa form|Poly [ADP-ribose] polymerase 1 antibody, 28-kDa form|PARP1|ADPRT|PPOL antibody
UniProt ID
P09874
Observed MW
115 kDa, 89 kDa
Application
Tested Applications
ELISA, WB, IHC, IF
Recommended dilution
WB: 1:5000 - 1:30000; IHC: 1:100 - 1:1000; IF: 1:50 - 1:500
Validated Images
HeLa cells were subjected to SDS PAGE followed by western blot with FNab09939(PARP1 Antibody) at dilution of 1:20000
Immunohistochemistry of paraffin-embedded human breast cancer using FNab09939(PARP1 antibody) at dilution of 1:600
Immunofluorescent analysis of HeLa cells using FNab09939 (PARP1 antibody) at dilution of 1:100 and Alexa Fluor 488-conjugated Goat Anti-Mouse IgG(H+L)
Background
PARP1 (poly(ADP-ribose) polymerase 1) is a nuclear enzyme catalyzing the poly(ADP-ribosyl)ation of many key proteins in vivo. The normal function of PARP1 is the routine repair of DNA damage. Activated by DNA strand breaks, the PARP1 is cleaved into an 85 to 89-kDa COOH-terminal fragment and a 24-kDa NH2-terminal peptide by caspases during the apoptotic process. The appearance of PARP fragments is commonly considered as an important biomarker of apoptosis.
How many times can antibodies be recycled?

First, usually it's not suggested to recycle antibodies. After use, buffer system of antibodies has changed. The storage condition of recycled antibodies for different customers also varies. Thus, the performance efficiency of recycled antibodies can’t be guaranteed. Besides, FineTest ever conducted the antibody recycling assay. Assay results show recycling times of different antibodies also varies. Usually, higher antibody titer allows more repeated use. Customers can determine based on experimental requirements.

Notes: After incubation, we recycle rest antibodies to centrifuge tube and store at 4℃. High titer antibodies can be stored for a minimum of one week. Reuse about three times.

What are components of FineTest antibody buffer?

Components of FineTest antibody buffer are usually PBS with proclin300 or sodium azide, BSA, 50% glycerol. Common preservative is proclin300 or sodium azide, which is widely applied in the lab and industry.

How about the storage temperature and duration of FineTest antibodies?

Most antibodies are stored at -20℃. Directly-labeled flow cytometry antibodies should be stored at 2 - 8℃. The shelf life is one year. If after sales issues for purchased antibodies appear, return or replacement is available. Usually, antibodies can be still used after the one-year warranty. We can offer technical support services.

Is dilution required for FineTest antibodies? What’s the dilute solution?

Directly-labeled flow cytometry antibodies are ready-to-use without dilution. Other antibodies are usually concentrated. Follow the dilution ratio suggested in the manual. Dilute solution for different experiments also varies. Common antibody dilution buffers are acceptable(e.g. PBST, TBST, antibody blocking buffer).

How to retrieve antibodies for immunohistochemistry?

Common retrieval buffers: Tris-EDTA Buffer(pH 9.0); Citrate Buffer(pH 6.0)

Heat induced antibody retrieval:

Method 1: Water-bath heating: Put the beaker with retrieval buffer and slide in the boiling water bath. Keep the boiling state for 15min. Naturally cool to room temperature;

Method 2: Microwave retrieval: Put the beaker with retrieval buffer and slide in the microwave oven. Heat at high power for 5min, Switch OFF for 3min, Heat at medium power for 5min. Naturally cool to room temperature.

How to choose secondary antibodies?

(1) Secondary antibodies react with primary antibodies. Thus, secondary antibodies should be against host species of primary antibodies. E.g. If the primary antibody is derived from rabbit, the relevant secondary antibody should be against rabbit. E.g. goat anti rabbit or donkey anti rabbit.

(2) Choose secondary antibody conjugates according to the experimental type, e.g. ELISA, WB, IHC etc. Common enzyme conjugated secondary antibodies are labelled by HRP, AP etc. Fluorescin or dye labelled secondary antibodies are applied in immunofluorescence and flow cytometry(e.g. FITC, Cy3).

Product Comparison