Effects of Fc Receptor on Flow Cytometry

Abstract: Fc receptor(FcR) is the cell surface protein specifically binding with Fc fragment of antibodies. Different immunocytes express different types of FcR to recognize relevant antibodies. In flow cytometry, IgG monoclonal antibodies are commonly used for staining, and mainly bind with Fcγ receptor(FcγR). According to affinity differences in IgG Fc fragment, FcγR contains three subgroups: high affinity FcγRI(CD64), low affinity FcγRII(CD32) and FcγRIII(CD16). These receptors are widely expressed in monocytes, macrophages, dendritic cells, NK cells and some T cells. Unblocking leads to non-specific antibody binding and interferes with detection result during flow cytometry. Thus, Fc blocker usually improves staining specificity.

Keywords: Fc Receptor, Fc Blocker, Fc Blocking Flow Cytometry, Staining Specificity

1. Expression of Fcγ Receptor

Fcγ receptor is widely expressed on the surface of various immunocytes. Subtype distribution in cells are specific: FcγRI(CD64) is usually found in monocytes, macrophages, dendritic cells(DC), activated neutrophils and eosinophils; FcγRII includes FcγRIIa(expressed in neutrophils, monocytes and DC), FcγRIIb(distributed in B cells and myeloid cells) and FcγRIIc(distributed in monocytes/macrophages, neutrophils, and NK cells); FcγRIII includes FcγRIIIa(medium affinity, widely expressed in various white blood cells) and FcγRIIIb(low affinity, limited to neutrophils). In flow cytometry staining, high expression of FcγR in target cells enables the possible non-specific binding with Fc fragment of IgG antibody, resulting in increased background and even false positive signal. Thus, Fc blocker(e.g. anti- CD16/32 antibody) usually blocks Fc receptor before the experiment, ensuring specific staining and reliable data.

Expression of Fcγ Receptor

2. Types of Fc Receptor

According to bound immunoglobulin, Fc receptor(FcR) can be divided into five types: FcγR(IgG), FcεR(IgE), FcαR(IgA), FcμR(IgM) and FcδR(IgD). IgG monoclonal antibody binds with FcγR. Based on different affinity to IgG Fc fragment, FcγR is divided into three subgroups: high affinity FcγRI(CD64) > medium affinity FcγRIII(CD16) > low affinity FcγRII(CD32). Affinity differences directly affect non-specific antibody binding with cells expressing FcγR, and should be primarily considered in flow cytometry staining.

Types of Fc Receptor

3. Effects on Flow Cytometry

Fc receptor(FcR) obviously affects experimental accuracy during flow cytometry, including:

Non-specific binding: Fc fragment of IgG flow cytometry antibody can bind with FcγR on the cell surface(e.g. CD16, CD32, CD64), resulting in adhesion of antibody on non-target cell and false positive signal.

Increased background: In cells highly expressing FcR(e.g. monocytes, macrophages, dendritic cells, NK cells, activated neutrophils), unblocking FcR obviously increases staining background and decreases signal-to-noise ratio.

Masking of weak positive signal: Non-specific binding may mask real signal of lowly expressed antigen, affecting accurate recognition of rare or weakly positive cell populations(e.g. some T cell subpopulations).

Interference of multicolor panel: In high-dimensional flow cytometry analysis, FcR mediated non-specific staining may leak to multiple detection channels, interfering with compensation and gating setting.

Variations among batches or samples: Expression level of FcR in different samples changes(e.g. inflammation). Unblocking decreases experimental reproducibility.

Thus, blocking Fc receptor with Fc blocker(e.g. anti- CD16/32 antibody) before staining plays an important role in maintaining specificity, sensitivity and reproducibility of flow cytometry data.

Recommended Products
Species Cell Populations Flow Cytometry Antibody Combination Cat.No
Human T/B/NK cell populations detection CD45-PerCP PCP-30039
CD3-FITC FITC-30004
CD16-PE PE-30061
CD56-PE PE-30008
CD19-APC APC-30066
Human Thl/Th2 cell populations detection CD3-PerCP/Cyanine5.5 PCP55-30004
CD4-FITC FITC-30005
IFN-γ-PE PE-30053
IL4-APC APC-30043
Mouse Thl/Th2 cell populations detection CD3-PerCP/Cyanine5.5 PCP55-30002
CD4-FITC FITC-30128
IFN-γ-PE PE-30074
IL4-APC APC-30026
Human Treg cell populations detection CD4-FITC FITC-30005
CD25-PE PE-30035
CD3-PerCP-Cy5.5 PCP55-30004
CD127-FineTest®647 F647-30033
Mouse Treg cell populations detection CD4-FITC FITC-30128
CD25-APC APC-30017
FOXP3-PE PE-30111

REFERENCES

[1]Optimization of the Blocking and Signal Preservation Protocol in High-Parameter Flow Cytometry, PMID: 40996492.
[2]Nipocalimab, an immunoselective FcRn blocker that lowers IgG and has unique molecular properties, PMID: 39936406.

Product Comparison