Mouse Anti-MPV IgM(Anti-Monkeypox Virus IgM) ELISA Kit

This kit is based on indirect ELISA detection method and takes 3h assay time. The microplate provided in this kit has been precoated with antigen. HRP-antibody is used as detection antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add HRP-detection antibody, then it binds with Anti-MPV IgM bound to precoated antibody. Wash unbound components and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of Anti-MPV IgM in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.

Catalogue No.: 
EM2128
Alias: 
MPXV IgM ELISA Kit, Monkeypox virus IgM ELISA Kit
Species: 
Mouse
Range: 
1.563-100ng/ml
Sensitivity: 
0.938ng/ml
Size Price
96T Inquiry
48T Inquiry
ETA of in-stock products: 2 Weeks
  • SPECIFICATIONS
  • FIGURES
  • CONDITIONS
  • FAQS
Product Name
Mouse Anti-MPV IgM(Anti-Monkeypox Virus IgM) ELISA Kit
Alias
MPXV IgM ELISA Kit, Monkeypox virus IgM ELISA Kit
Catalogue No.
EM2128
Size
48T/96T
Species
Mouse
Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Method
Indirect ELISA
Detection Wavelength
OD450
Reaction Duration
1.5 hours
Range
1.563-100ng/ml
Sensitivity
0.938ng/ml
Storage
2-8°C(Sealed), Don't cryopreserve.
Specificity
Specifically binds with Anti-MPV IgM , no obvious cross reaction with other analogues.
Required Instruments and Reagents
  1. Microplate reader (wavelength: 450nm)
  2. 37°C incubator (CO2 incubator for cell culture is not recommenced.)
  3. Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
  4. Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
  5. Sterile tubes and Eppendorf tubes with disposable tips
  6. Absorbent paper and loading slot
  7. Deionized or distilled water
Assay Procedure Summary
Elisa实验原理图
Standard Curve

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)

Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(ng/ml) OD-1 OD-2 Average
0 0.103 0.107 0.105
1.562 0.17 0.174 0.172
3.125 0.227 0.233 0.23
6.25 0.37 0.38 0.375
12.5 0.587 0.605 0.596
25 0.971 0.999 0.985
50 1.694 1.744 1.719
100 2.232 2.296 2.264
EM2128 Standard Curve Image
Recovery

Add a certain amount of Anti-MPV IgM into the sample. Calculate the recovery by comparing the measured value with the expected amount of Anti-MPV IgM in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 96-102 100
EDTA plasma(n=10) 86-103 97
Heparin plasma(n=10) 85-102 96
Linearity

Dilute the sample with a certain amount of Anti-MPV IgM at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 88-102% 85-92% 91-100%
EDTA plasma(n=10) 85-104% 89-100% 85-97%
Heparin plasma(n=10) 86-95% 87-100% 88-99%
Precision(%)

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (ng/ml) 3.07 12.18 47.85 3.11 11.87 46.35
Standard deviation 0.14 0.63 2.19 0.17 0.7 1.97
CV(%) 4.58 5.16 4.58 5.32 5.86 4.26
Stability

Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.

ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months
Average(%) 80 95-100
About FineTest® ELISA Kits
What’s the plate size in FineTest® ELISA Kits?

The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).

How about the shelf life and stability of FineTest® ELISA Kits?

Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest® ELISA Kits have been subject to strict quality test.

Which cloned antibodies for FineTest® ELISA Kits are used?

These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.

Can I mix reagents from different batches of FineTest® ELISA Kits?

Not suggested. ELISA reagents are optimized for specific batch.

Can FineTest® ELISA Kits be used partially?

Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.

How long can the diluted lyophilized standard be stored for continual use?

Used up within 12h.

Can standard curve be extended to any direction?

FineTest® can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.

Sample Issues
Why does detection for serum/plasma sample by FineTest® ELISA Kits require for 1/2 dilution?

Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.

What’s the half-life of protein in serum/plasma/cell culture supernatant?

FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

What's the expected concentration for particularly analyzing my sample?

Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

How many samples can FineTest® ELISA Kits detect?

It depends on whether duplicate assay for your sample is required. Such as, you can detect 80 samples without duplication or 40 samples.

Operational Issues
Why is sample loading conducted after equilibrating all kits’ components and samples to room temperature?

Temperature is the important factor for ELISA binding reaction. The reaction of samples at a consistent temperature requires for equilibrating all reagents to room temperature before the assay, including tested samples. Avoid the inaccurate ELISA assay results caused by temperature differences.

Why is duplicate assay suggested for ELISA assay?

To get more accurate assay results, it's strongly suggested to conduct duplicate assay for the standard and sample. Duplicate assay can calculate average value to ensure more accurate assay results and solve drift caused by misoperation during the assay. Calculation of CV evaluates experimental operation and precision of the ELISA kit.

How to get the standard curve with excellent linearity?

Follow the suggested method in the manual to store the standard. Before dissolving the standard, transient centrifugation is required to completely collect the powder. Confirm the fully dissolution and mixing of the standard(about 10min). Then, conduct steps of series dilution. Ensure the fully mixing and accurate pipetting in each step. Properly stop the staining. Choose suitable fitting equation to plot the standard curve.

Can ELISA plates be stacked together for incubation?

To keep the consistent environmental condition of all plates, stacking is not suggested during incubation.

Why is polypropylene tube used for standard dilution in some analyses?

Some proteins or analytes can bind with glass or polystyrene. However, they are not easy to bind with polypropylene tube.

When to stop ELISA reaction?

ELISA assay finally requires for enzyme-catalyzed substrate to complete the staining reaction. Stopping the reaction at the best time is the important factor for successful ELISA assay. When the blue complex appears after adding TMB substrate for 12min, read the O.D. absorbance at 620nm. The staining can be stopped, when the OD value of the darkest color at 620nm is between 0.8 - 0.9. The relevant OD value at 450nm for stopping the staining is between 2.0 - 2.5. If the OD value at 620nm is lower than 0.8, the staining duration can be properly extended.

Why is dual wavelength selected for reading in a microplate reader? What's the purpose of wavelength correction?

Dual wavelength for reading in ELISA assay mainly aims to remove non-specific background interference, and improve accuracy and reliability of the detection. FineTest® usually suggests to set the corrected wavelength as 570nm or 630nm in a microplate reader. The OD value may be higher when directly reading at 450nm. However, the accuracy is lower.

Why is 4 - pl curve fitting is required for generating standard curve?

FineTest® recommends to use ELISA curve fitting software and validate ELISA kit with 4 - pl curve fitting. 4 - pl curve fitting mainly aims to accurately describe the nonlinear dynamic characteristics of antigen - antibody binding. Thus, the quantitative accuracy of low or high concentration of sample is improved. Experimental errors are decreased. The reliability and reproducibility of assay results are ensured.

If sample OD value is higher than OD value of the highest point on the standard curve, what's the suggested solution?

Dilute the sample with dilution buffer and conduct the detection again. Ensure the detected value of the sample falls in the range of standard curve.